SAE AS22759/88 (M22759/88)

Recommended Use:   

Used in critical aerospace applications where excellent electricals, cut through, abrasion resistance and the elimination of arc tracking is needed.

Conductor: Tin Coated Copper

Insulation: TFE/Polyimide Composite

Voltage Rating: 600

Temperature Rating: 150º C

PartAWGStrandingODMinODMaxWeight (lbs/1000 ft)
M22759/88-262619/380.0330.0371.55
M22759/88-242419/360.0380.0422.15
M22759/88-222219/340.0430.0473
M22759/88-202019/320.0510.0554.55
M22759/88-181819/300.0610.0656.7
M22759/88-161619/290.0680.0738.6
M22759/88-141419/270.0810.08612.95
M22759/88-121237/280.10.10520.1
M22759/88-101037/260.1220.12731.4
M22759/88-88133/290.180.18857.6
M22759/88-66133/270.2190.22988.3
M22759/88-44133/250.2760.288143
M22759/88-22665/300.3440.364222
M22759/88-11817/300.3880.408289
M22759/88-011/01045/300.420.45345
M22759/88-022/01330/300.4750.505432
M22759/88-033/01665/300.530.56542
M22759/88-044/02109/300.590.63681
M22759/1-22-X (X denotes color options as listed below):
Color Options: 0 = Black, 1 = Brown, 2 = Red, 3 = Orange, 4 = Yellow, 5 = Green, 6 = Blue, 7 = Violet, 8 = Gray, 9 = White
This specification can also be custom color coded with stripes.